Home>X-ray Diffractometer
X-ray Diffractometer
Model | Max Output | introduction | |
---|---|---|---|
Voltage(KV) | Power(W) | ||
|
30KV 40KV 50KV 60KV 65KV 70KV |
10W 30W 50W 65W 75W 100W |
1. Models from 10kV to 70kV, 10W to 100W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional USB, RS232, RS485 Ethernet Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11. Size 127.00mm x 75.00mm x203.00mm 12. OEM customization available |
|
20KV 30KV 40KV 50KV 60KV 70KV 75KV 100KV 160KV |
300W 600W 1200W |
1. Power factor corrected input 86Vac~265Vac 2. Models from 20KV to 160kV, 300W to 1.2kW 3. Integrated Filament Supply 5A@10Vdc 4. low output ripple and noise <0.1%p-p 5. high stability 0.02%/8 hour 6. low temperature coefficient 25ppm/℃ 7. Optional Ethernet, RS-232, RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. OEM customization available |
|
2KV 6KV 10KV 20KV 30KV 40KV 60KV 80KV 100KV 130KV 140KV 150KV 160KV 200KV 240KV 260KV |
20W 60W 120W 200W 300W 600W 1200W 2400W 4000W |
1. Input 220Vac±10%, single phase 38 amps 2. Models from 2KV to 260kV,4kW 3. Bipolar, positive, negative, easy to combine 5. low output ripple and noise <0.1%p-p 6. high stability 0.02%/8 hour 7. low temperature coefficient 25ppm/℃ 8. Ethernet, RS-232, Optional RS485 Digital Interfaces 9. Overvoltage, Arc and short circuit Protected 10. Voltage and current adjustment function 11. Local or remote control, or digital control 12. Safety interlock function 13. OEM customization available 14. CE certification |
|
2KV 4KV 6KV 8 KV 10KV 12KV 16KV 20KV 24KV 30KV 40KV 60KV 80KV 100KV 120KV 140KV 150KV 160KV 200KV 240KV 300KV 450 KV |
12000~192000W |
1. Input 360-528Vac, three phase 50 amps 2. Models from 2KV to 600kV,24kW 3. Bipolar, positive, negative, easy to combine 4. Parallel Capability 24kW, 36kW, 48kW...200kW 5. low output ripple and noise <0.1%p-p 6. high stability 0.02%/8 hour 7. low temperature coefficient 25ppm/℃ 8. Ethernet, RS-232, Optional RS485 Digital Interfaces 9. Overvoltage, Arc and short circuit Protected 10. Voltage and current adjustment function 11. Local or remote control, or digital control 12. Safety interlock function 13. OEM customization available 14. CE certification |
|
1KV 2KV 3KV 6KV 8KV 10KV 15KV 20KV |
6W 9W 15W 30W 60W 75W 100W |
1. Output from 0.6kv to 20kv @ 6w to 100w 2. Compact size, high power 3. Iow temperature coefficient 25ppm/℃ 4. Low output ripple and noise 0.1% p-p 5. High stability 0.01% per 8 hour 6. Local and remote voltage programming 7. Positive or negative output 8. Arc and short circuit protection 9. OEM customization available |
|
1KV 1.2KV 2KV 3KV 5KV 7.5KV 10KV 12KV 15KV 20KV 25KV 30KV |
6W 9W 15W 30W 60W 75W 100W |
1. Models from 3kV to 30kV, 6W to 100W 2. Option usb2.0,RS-232 or RS-422 serial interface 3. Low temperature coefficient 25ppm/ ℃ 4. Low output ripple and noise 0.001% p-p 5. High stability 0.01% per hour 6. Local and remote voltage programming 7. Positive or negative polarity 8. Arc and short circuit protection 9. Safety interlock circuit 10. Compact size 11. OEM customization available |
|
1KV 3KV 6KV 10KV 20KV 30KV 40KV 50KV 60KV 65KV |
10W 30W 50W 65W 75W 100W |
1. Output from 1kv to 65kv,10w to 100w 2. Option usb2.0,rs-232 or rs-422 serial interface 3. Low temperature coefficient 25ppm/ ℃ 4. Low output ripple and noise 0.1% p-p 5. High stability 0.01% per hour 6. Local and remote voltage to set 7. Positive or negative polarity 8. Arc and short circuit Protected 9. Safety interlock circuit 10. Compact size 11. OEM customization available |
|
160KV 225KV 320KV 450KV |
2000W 4000W |
1. Voltage 160kV, 225kV, 320kV, 450kV can be selected, 2.2000W, 4000W other power requirements can be customized 3. A variety of X-ray tube characteristic curves can be stored 4. Wide voltage input 90Vac-265Vac 5. Integrated large and small filament power supply overvoltage, arcing and output short circuit protection 6. Network port, RS-232, RS485 digital communication 7. Excellent stability, low ripple, small size 8. Safety interlock function 9. Can be customized according to user requirements |