Home>X-ray Industrial Imaging
X-ray Industrial Imaging
Model | Max Output | introduction | |
---|---|---|---|
Voltage(KV) | Power(W) | ||
|
3KV 5KV 10KV 15KV 20KV 30KV |
15W |
1. Input voltage 105Vac~125Vac or 210Vac~250Vac. 2. Output voltage 30kVmax, output power 15W. 3. Low output ripple and noise≤ 0.05%p-p. 4. High stability 0.01% per hour. 5. Low temperature coefficient 25ppm/℃. 6. Strong arc protection and short circuit protection. 7. External potentionmeter or external control voltage to set. 8. Air insulation, the mimum storage is 200mJ. 9. Postive or Negative output. 10. OEM customization available |
|
6KV 7.5KV 10KV 12KV 15KV 20KV 25KV 30KV |
6W 9W 15W 30W 60W 75W 100W |
1. Models from 10KV to 30kV, 6W to 100W 2. Integrated Filament Supply 3a@5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.01%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional USB2.0, RS-232, RS485 Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11.Small size 65.00mm x 115.00mm x150.00mm 12. OEM customization available |
|
10KV 20KV 30KV 40KV 50KV |
10W 30W 50W |
1. Models from 10KV to 50kV, 10W to 50W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional Ethernet, RS-232, RS485 Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11.Small size,45% Smaller than XRN 12. OEM customization available |
|
10KV 20KV 30KV 40KV 50KV 60KV 70KV |
10W 20W 30W 40W 50W 60W 70W 80W 90W 100W |
1. Models from 10KV to 70kV, 10W to 100W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional Ethernet, RS-232, RS485 Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11.Small size ,30% Smaller than XRN 12. OEM customization available |
|
10KV 20KV 30KV 50KV 65KV 70KV |
10W 30W 50W 65W 75W 100W |
1. Models from 10kV to 70kV, 10W to 100W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional USB, RS232, RS485 Ethernet Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11. Size 127.00mm x 75.00mm x203.00mm 12. OEM customization available 13. Soon to be discontinued, not recommended |
|
30KV 40KV 50KV 60KV 65KV 70KV |
10W 30W 50W 65W 75W 100W |
1. Models from 10kV to 70kV, 10W to 100W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional USB, RS232, RS485 Ethernet Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11. Size 127.00mm x 75.00mm x203.00mm 12. OEM customization available |
|
25KV 30KV 50KV 60KV 65KV |
50W 65W 75W 100W |
1. Models from 25KV to 65kV, 50W to 100W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6.Optional B Integrated BIAS Supply 7. Optional USB, RS-232, RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. Size 73.00mm x 100.00mm x203.00mm 13. OEM customization available 14. Discontinued soon, not recommended |
|
10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV |
120W |
1. Power factor corrected input 86Vac~265Vac 2. Models from 10KV to 70kV, 120W 3. Integrated Filament Supply 3.5A@5.5Vdc 4. low output ripple and noise <0.1%p-p 5. high stability 0.02%/8 hour 6. low temperature coefficient 25ppm/℃ 7. Optional Ethernet, RS-232, RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. OEM customization available |
|
20KV 25KV 30KV 35KV 40KV 50KV 60KV 65KV 70KV 80KV 100KV 120KV 125KV 130KV 150KV 160KV |
75W 90W 100W 120W 150W 200W |
1. Models from 10KV to 100kV, 75W to 200W 2. Integrated Filament Supply 3.5A@5.5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional USB, RS-232, RS485 Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11. OEM customization available |
|
20KV 40KV 60KV 70KV 80KV 100KV 120KV 140KV |
75W 90W 100W 120W 150W 200W 280W |
1. Models from ±40KV to ±70kV, 90W to 300W 2. Integrated Floating Filament Supply 4A@5Vdc 3. low output ripple and noise <0.1%p-p 4. high stability 0.02%/8 hour 5. low temperature coefficient 25ppm/℃ 6. Optional USB, RS-232, RS485 Digital Interfaces 7. Overvoltage, Arc and short circuit Protected 8. Voltage and current adjustment function 9. Local or remote control, or digital control 10. Safety interlock function 11. OEM customization available 12. Bipolar output X-Ray generators |
|
10KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV |
10W 30W 60W 150W 300W |
1. Input 220Vac±10%,10A 2. Models from 10KV to 130kV, 10W to 300W 3. Integrated Filament Supply 3A@3Vdc 4. low output ripple and noise <0.1%p-p 5. high stability 0.02%/8 hour 6. low temperature coefficient 25ppm/℃ 7. Ethernet, RS-232, Optional RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. OEM customization available |
|
20KV 30KV 40KV 50KV 60KV 70KV 75KV 100KV 160KV |
300W 600W 1200W |
1. Power factor corrected input 86Vac~265Vac 2. Models from 20KV to 160kV, 300W to 1.2kW 3. Integrated Filament Supply 5A@10Vdc 4. low output ripple and noise <0.1%p-p 5. high stability 0.02%/8 hour 6. low temperature coefficient 25ppm/℃ 7. Optional Ethernet, RS-232, RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. OEM customization available |
|
40KV 60KV 80KV 100KV 120KV 140KV |
300W 600W 1200W |
1. Power factor corrected input 86Vac~265Vac 2. Models from ±20KV to ±160kV, 300W to 1.2kW 3. Integrated Floating Filament Supply 5A@10Vdc 4. low output ripple and noise <0.1%p-p 5. high stability 0.02%/8 hour 6. low temperature coefficient 25ppm/℃ 7. Optional Ethernet, RS-232, RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. OEM customization available 13. Bipolar output X-Ray generators |
|
20KV 30KV 40KV 50KV |
50W |
1.Fully digitally controlled. 2,Focus size of the X-ray tube is 35um. 3.Output voltage isN50kV MAX. 4.Output current is 1mA MAX. 5.Power is 50W MAX. 6.Order number: X-RAY TUBE: P/N: 50501-Cu-B Target Material: Cu P/N: 50501-W-B Target Material: W P/N: 50501-Mo-B Target Material: Mo High voltage power supply: P/N: XRW50P50-B-RS232 P/N: XRW50P50-B-RS422 |