Home>High Voltage Amplifiers
High Voltage Amplifiers
Model | Max Output | introduction | |
---|---|---|---|
Voltage(KV) | Power(W) | ||
|
10KV |
20W |
1. Output voltage: 0 to ±10 kV DC or peak AC 2. Output current: 0 to ±2 mA DC or peak AC 3. Slew rate: > 35 V / μs 4. Large signal bandwidth: DC to more than 1.2khz (-3dB) 5. DC voltage gain: 1000 V/V 6. OEM customization available 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system to ensure high precision 10. Take advantage of complete solid state design and maintenance-free design 11. Prevent overvoltage and overcurrent conditions generated by active load 12. Drive capacitive load through four quadrant output |
|
0.7KV |
80W |
1. Output voltage: bipolar 0 to ±700V, unipolar 1.4kV DC or peak AC 2. Output current: bipolar 0 to ±100 mA, unipolar ±50 mA DC or peak AC 3. Slew rate: bipolar over 380 V/μs, unipolar over 370 V/μs, 4. Large signal bandwidth: DC to greater than 1.2kHz (-3dB) 5. DC voltage gain: 0-300 V/V adjustable 6. OEM cutomization available 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system ensures high precision 10. Take advantage of the complete solid-state design and maintenance-free design 11. Protection against over-voltage and over-current conditions generated by active loads 12. Drive capacitive loads with four-quadrant output |
|
10KV |
100W |
1. Output voltage: 0 to ±10kVDC or peak AC 2. Output current: 0 to ±10 mA DC or 40mA peak AC for 1 ms 3. Slew rate: greater than 150 V/μs 4. Large signal bandwidth: DC to greater than 15kHz (-3dB) 5. DC voltage gain: 500 V/V 6. OEM customization available 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system ensures high precision 10. Take advantage of the complete solid-state design and maintenance-free design 11. Protection against overvoltage and overcurrent conditions generated by active loads 12. Drive capacitive loads with four-quadrant output |
|
10KV |
600W |
1.Output voltage: 0 ~±10kv DC or AC peak 2.Output current: 0 ~±60 mA DC or AC peak 3.Slew rate: greater than 1000 V/μs 4.Large signal bandwidth :DC to greater than 10khz(2% distortion) 5.Small signal bandwidth: DC to greater than 20kHz (-3dB) 6.Dc voltage gain: 1000V /V 7.0-10 kV settling time (to 1%) less than 200 μs 8. Dynamic adjustment to optimise AC response for various load parameters 9. Local and remote high voltage on/off function, short circuit protection 10. Low output noise, closed loop system to ensure high accuracy 11. Utilises complete solid state design and maintenance free design 12. Prevent over-voltage and over-current conditions generated by active loads 13. Drive capacitive loads through four-quadrant outputs 14. OEM customisation available |
|
20KV |
400W |
1. Output voltage: 0 to ±20 kV DC or peak AC |
|
2KV |
3W |
1.Output voltage ±300V-±2KV 2. Reverse speed: 50V/us 3. In-phase proportional amplifier 4.four-quadrant output driving load 5. closed loop system,low noise, high precision 6. With short circuit protection 7.can be used as DC power supply |
|
2KV |
400W |
1. Output voltage: 0 to ±2 kV DC or peak AC 2. Output current: 0 to ±200 mA DC or ±400 mA peak AC 3. Slew rate: greater than 750 V / μs 4. Large signal bandwidth: DC to greater than 60kHz (-3dB) 5. DC voltage gain: 200 V / V 6. OEM cutomization available 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
5KV |
400W |
1. Output voltage: 0 to ±5 kV DC or peak AC 2. Output current: 0 to ±80 mA DC peak AC 3. Slew rate: greater than 1000 V / μs 4. Large signal bandwidth: DC to greater than60kHz (-3dB) 5. DC voltage gain: 500 V / V 6. OEM cutomization available 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
7.5KV |
400W |
1. Output voltage: 0 to ±7.5 kV DC or peak AC 2. Output current: 0 to ±50 mA DC or peak AC 3. Slew rate: > 1000 V / μs 4. Large signal bandwidth: DC to greater than 15kHz(-3dB) 5. DC voltage gain: 750 V / V 6. OEM customization available 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
20KV |
400W |
1. Output voltage: 0 to ±20 kV DC or peak AC 5. DC voltage gain: 2000 V / V 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
10KV |
400W |
1.Output voltage: 0 to ±10 kV DC or peak AC 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
5KV |
100W |
1.Output voltage: 0 to ±5 kV DC or peak AC 7. Dynamically adjust to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system guarantees high accuracy 10. Utilizes complete solid-state design and maintenance-free design 11. Prevents overvoltage and overcurrent conditions generated by active loads 12. Drives capacitive loads through four-quadrant output |
|
0.05KV 0.1KV 0.2KV 0.3KV 0.4KV 0.5KV 0.6KV 0.8KV 1KV 1.25KV 1.5KV 2KV |
1W 2W |
1.Output voltage±50v~±2kv 4.Fast reversing, slewing & settling 7.Temperature coefficient 10ppm/℃ 8. Voltage regulatioLoad regulation 0.001% 10. Arc & short circuit protection 11.OEMn 0.001% 9. customization available |
|
30KV |
600W |
1. Output voltage: 0 to ±30 kV DC or peak AC 2. Output current: 0 to ±20 mA DC or peak AC 3. Conversion rate: greater than 550 V / μs 4. Large signal bandwidth: DC to greater than 2.5kHz (-3dB) 5. DC voltage gain: 3000 V / V 6. OEM customization 7.0-30 kV settling time (to 1%) is less than 200 μs 8. Dynamic adjustment to optimize AC response for various load parameters 9. Local and remote high voltage on/off function, short circuit protection 10. Low output noise, closed loop system to ensure high accuracy 11. Utilize complete solid-state design and maintenance-free design 12. Prevent over-voltage and over-current conditions generated by active loads 13. Drive capacitive load through four-quadrant output |
|
40KV |
600W |
1. Output voltage: 0 to ±40 kV DC or peak AC 2. Output current: 0 to ±15 mA DC or peak AC 3. Conversion rate: greater than 350 V / μs 4. Large signal bandwidth: DC to greater than 2.5kHz (-3dB) 5. DC voltage gain: 4000 V / V 6. Customers can customize by OEM 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed loop system to ensure high accuracy 10. Utilize complete solid-state design and maintenance-free design 11. Prevent over-voltage and over-current conditions generated by active loads 12. Drive capacitive load through four-quadrant output |
|
50KV |
600W |
1. Output voltage: 0 to ±40 kV DC or peak AC 2. Output current: 0 to ±15 mA DC or peak AC 3. Conversion rate: greater than 350 V / μs 4. Large signal bandwidth: DC to greater than 2.5kHz (-3dB) 5. DC voltage gain: 4000 V / V 6. Customers can customize by OEM 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed loop system to ensure high accuracy 10. Utilize complete solid-state design and maintenance-free design 11. Prevent over-voltage and over-current conditions generated by active loads 12. Drive capacitive load through four-quadrant output
|
|
60KV |
600W |
1. Output voltage: 0 to ±60 kV DC or peak AC 2. Output current: 0 to ±10 mA DC or peak AC 3. Conversion rate: greater than 350 V / μs 4. Large signal bandwidth: DC to greater than 1.2 kHz (2% distortion) 5. DC voltage gain: 6000 V / V 6. OEM customization. 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed loop system to ensure high accuracy 10. Utilize complete solid-state design and maintenance-free design 11. Prevent over-voltage and over-current conditions generated by active loads 12. Drive capacitive load through four-quadrant output |
|
4KV |
80W |
1. Output voltage: 0 to ±4 kV DC or peak AC 2. Output current: 0 to ±20 mA DC or peak AC 3. Slew rate: > 35 V / μs 4. Large signal bandwidth: DC to more than 13khz (-3dB) 5. DC voltage gain: 1000 V/V 6. OEM customization available 7. Dynamic adjustment to optimize AC response for various load parameters 8. Local and remote high voltage on/off function, short circuit protection 9. Low output noise, closed-loop system to ensure high precision 10. Take advantage of complete solid state design and maintenance-free design 11. Prevent overvoltage and overcurrent conditions generated by active load 12. Drive capacitive load through four quadrant output |