Home>Rack mount
Rack mount
| Model | Max Output | introduction | |
|---|---|---|---|
| Voltage(KV) | Power(W) | ||
|
|
1KV 2KV 3KV 6KV 8KV 10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV |
10W 30W 60W 100W 150W 300W 600W 1200W |
1. AC/DC output voltage up to 130KV, output power 1200W 2. Ripple voltage: 0.1% P-P, Temperature coefficient: ≤25ppm/℃ 3. Stability: Less than 100ppm per hour after 30 minutes of operation 4. Two chassis heights, multiple models available, CE certified 5. Maximum output voltage selectable from 1KV to 130KV, maximum power 1200W 6. 1U maximum output power: 400W, 600W, 750W selectable 7. Overvoltage, arc fault, and output short-circuit protection 8. Voltage and current regulation functions 9. Local or remote control 10. Safety interlock function 11. Customizable according to user requirements 12. High stability 13. Standard Ethernet port, RS-232, optional RS-485 control |
|
|
0.5KV 1KV 2KV 3KV 5KV 8KV 10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV |
2000W |
1. AC/DC output voltage up to 100kV, output power 2000W 2. Ripple voltage: 0.1% P-P +1Vrms. Temperature coefficient: 100ppm 3. Stability: Less than 100ppm per hour after half an hour of operation 4. Standard RS232, optional RS485 control via Ethernet port 5. Maximum output voltage selectable from 1kV to 100kV, maximum power 2kW 6. AC 220V power supply 7. Overvoltage, arc discharge, and output short-circuit protection 8. Voltage and current regulation functions 9. Local or remote control 10. Safety interlock function 11. Customizable according to user requirements 12. High stability, CE certified (EU) |
|
|
150KV 160KV 180KV 200KV 300KV |
2000W |
1. AC/DC output voltage up to 300KV, output power 2000W 2. Ripple voltage: 0.05% P-P + 1Vrms, Temperature coefficient: 25ppm 3. Stability: Less than 0.02% per hour after half an hour of operation 4. Standard Ethernet port, RS-232, optional RS-485 control 5. Maximum output voltage 150kV, 200kV with maximum power of 2000W, 300kV customizable 6. AC 220V power supply 7. Overvoltage, arc fault, and output short-circuit protection 8. Voltage and current regulation functions 9. Local or remote control 10. Safety interlock function 11. Customizable according to user requirements 12. High stability, low ripple 13. CE certified (EU) |
|
|
8KV 10KV 12KV 15KV 20KV 25KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV |
3000W |
1. AC/DC output voltage 100KV, output power 3kW 2. Ripple voltage: 0.05%. Temperature coefficient: ≤100ppm/℃. 3. Stability: After starting for half an hour, 0.01%/h, 0.05% every 8 hours. 4. Low starting voltage, fast response, strong resistance to ignition 5. Over voltage, over temperature, arc and output short circuit protection 6. Voltage and current regulation function 7. Local or remote control 8. Security interlock function 9. OEM customization available 10.SEMI certification |
|
|
8KV 10KV 12KV 15KV 20KV 25KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 125KV 150KV |
5000W |
1. AC/DC output voltage: 150KV, output power: 5kW 2. Ripple voltage: 0.05% P-P, Temperature coefficient: 100ppm 3. Stability: Less than 0.01% per hour after 1 hour of operation 4. Low starting voltage, fast response, strong arc resistance 5. AC 220V three-phase or AC 380V three-phase power supply 6. Over-voltage, over-temperature, arc and output short-circuit protection 7. Voltage and current adjustment functions 8. Local or remote control 9. Safety interlock function 10. Customizable according to user requirements 11. SEMI certified |
|
|
1KV 2KV 3KV 4KV 6KV 10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 90KV 100KV 120KV |
3000W 4000W 6400W |
1. AC/DC output voltage 120KV, output power 3kW, 4kW, 6.4kW 2. Ripple voltage: 0.1% P-P Temperature coefficient: 25ppm/℃ 3. Stability: Less than 0.02% per hour after 1 hour of operation 4. Standard Ethernet port, RS-232, optional RS-485 control 5. AC220V or AC380V power supply 6. Over-voltage, arc fault, and output short-circuit protection 7. Voltage and current adjustment functions 8. Local or remote control 9. Safety interlock function 10. Customizable according to user requirements 11. CE certified (European Union) |
|
|
1KV 2KV 3KV 4KV 6KV 8KV 10KV 12KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV 150KV 200KV 250KV 300KV |
6000W |
1. AC/DC output voltage up to 300KV, output power 6000W 2. Ripple voltage: 0.1% P-P +1Vrms. Temperature coefficient: 25ppm 3. Stability: Less than 0.02% per hour after half an hour of operation. 4. Output polarity can be reversed 5. Standard Ethernet port, RS-232C, optional RS-485 control 6. Overvoltage, overcurrent, and output short-circuit protection 7. Voltage and current regulation functions 8. Remote control of voltage and current 9. Safe interlock function 10. Customizable according to user requirements 11. CE certified (European Union) |
|
|
1KV 2KV 3KV 4KV 6KV 8KV 10KV 12KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV 150KV 200KV 225KV 250KV 300KV |
6000W |
1. AC/DC output voltage up to 300KV, output power 6000W 2. Ripple voltage: 0.1% P-P +1Vrms. Temperature coefficient: 25ppm 3. Stability: Less than 0.02% per hour after half an hour of operation 4. Standard Ethernet port, RS-232, optional RS-485 control 5. Overvoltage, arc fault, and output short-circuit protection 6. Voltage and current regulation functions 7. Local or remote control 8. Safety interlock function 9. Customizable according to user requirements 10. CE certified (European Union) |
|
|
1KV 2KV 3KV 4KV 6KV 8KV 10KV 12KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV 150KV 225KV |
12000W 24000W 36000W 48000W 60000W 72000W 84000W 96000W |
1. Input 360-528Vac, three phase 25 amps 2. Models from 1KV to 300kV,12kW 3. Parallel Capability 24kW, 36kW, 48kW...100kW 4. low output ripple and noise <0.1%p-p 5. high stability 0.02%/8 hour 6. low temperature coefficient 25ppm/℃ 7. Ethernet, RS-232, Optional RS485 Digital Interfaces 8. Overvoltage, Arc and short circuit Protected 9. Voltage and current adjustment function 10. Local or remote control, or digital control 11. Safety interlock function 12. OEM customization available 13. CE certification |
|
|
2KV 6KV 10KV 20KV 30KV 40KV 60KV 80KV 100KV 130KV 140KV 150KV 160KV 200KV 240KV 260KV |
20W 60W 120W 200W 300W 600W 1200W 2400W 4000W |
1. AC/DC output voltage up to 260KV, output power 4000W 2. Ripple voltage: 0.1% P-P +1Vrms. Temperature coefficient: 25ppm 3. Stability: Less than 100ppm per hour after half an hour of operation 4. One unit can be used as three units; fiber optic control is optional 5. Standard Ethernet port, RS-232C, optional RS-485 control 6. Over-voltage, over-current, and output short-circuit protection 7. Voltage and current adjustment functions 8. Remote control of voltage and current 9. Safe interlock function 10. Customizable according to user requirements 11. Available as an option for all Wisman high-voltage power supply chassis models 12. CE certified (European Union) |
|
|
2KV 4KV 6KV 8KV 12KV 16KV 20KV 24KV 30KV 40KV 60KV 70KV 80KV 100KV 120KV 140KV |
8000W |
1. AC/DC output voltage up to 140KV, output power 8000W 2. Ripple voltage: 0.1% P-P +1Vrms. Temperature coefficient: 25ppm 3. Stability: Less than 0.02% per hour after half an hour of operation 4. Fiber optic control optional 5. Standard Ethernet port, RS-232C, optional RS-485 control 6. Overvoltage, overcurrent, and output short-circuit protection 7. Voltage and current regulation functions 8. Remote voltage and current adjustment 9. Safe interlock function 10. Customizable according to user requirements 11. Available as an option for all Wisman high-voltage power supply chassis models |
|
|
2KV 4KV 6KV 8KV 12KV 16KV 20KV 24KV 30KV 40KV 60KV 70KV 80KV 100KV 120KV 140KV 160KV 200KV 240KV 300KV |
24000W |
1. AC/DC output voltage up to 300KV, output power 24000W 2. Ripple voltage: 0.1% P-P +1Vrms. Temperature coefficient: 25ppm 3. Stability: Less than 0.02% per hour after half an hour of operation 2. Fiber optic control optional 3. Standard Ethernet port, RS-232C, optional RS-485 control 4. Overvoltage, overcurrent, and output short-circuit protection 5. Voltage and current adjustment functions 6. Remote voltage and current adjustment capabilities 7. Safe interlock function 8. Customizable according to user requirements 9. Available as an option for all Wisman high-voltage power supply chassis models |
|
|
1KV 2KV 3KV 4KV 6KV 8KV 10KV 12KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130KV 150KV |
10~2000000W |
1. Output voltage from 1KV to 150KV, power from 10W to 2000KW 2. Fiber optic control available 3. Standard Ethernet port, RS-232C, optional RS-485 control 4. Overvoltage, overcurrent, and output short-circuit protection 5. Voltage and current regulation functions 6. Remote control of voltage and current 7. Safe interlock function 8. Customizable according to user requirements 9. Available for all Wisman high-voltage power supply chassis models |
|
|
5KV |
5000W |
1. Shore-based power supply, marine power supply, shipboard power supply 2. Power supply for deep-sea observation networks; high-voltage DC transmission; long-distance power transmission; scientific research, etc. 3. Full range of dry contact closures available for remote station alarm monitoring 4. Fully programmable electronic test load, capable of dissipating 5kW 5. Electrode functionality provided 6. Single cabinet. Safety interlock provided on the rear door 7. Inverter can be sold separately |
|
|
1KV 2KV 3KV 6KV 8KV 10KV 15KV 20KV 30KV 40KV 50KV 60KV 70KV 80KV 100KV 120KV 130 KV |
10W 30W 60W 100W 150W 300W 600W 1200W 2000W |
1. AC/DC output voltage up to 130KV, output power 2000W 2. Ripple voltage: 0.05% P-P (0.01%p-p can be customized) Temperature coefficient: ≤25ppm/℃ 3. Stability: less than 100ppm/1 hour after starting for half an hour, less than 500ppm/ 8 hours. 4. The starting voltage is low, and it can work stably from 15V 5. 2 kinds of rack mount heights, a variety of models are optional, passed the EU CE certification 6. AC AC220V power supply, optional AC110V power supply, power factor 0.995 7. Strong ability to carry fire, suitable for accelerators and ion beam implantation applications 8. Overvoltage, arc and output short circuit protection, fast ignition recovery speed, 9. Voltage and current automatic cross adjustment function 10. Local or remote control 11. Safety interlock function, high and low level start and stop function 12. OEM customization available 13. High stability 0.01%, low ripple 0.05% 14. Standard ethernet, RS-232, optional RS-485 control |